Effect of poly-hexamethylene biguanide hydrochloride (PHMB) treated non-sterile medical gloves upon the transmission of Streptococcus pyogenes, carbapenem-resistant E. coli, MRSA and Klebsiella pneumoniae from contact surfaces

Abstract

Background

Reduction of accidental contamination of the near-patient environment has potential to reduce acquisition of healthcare-associated infection(s). Although medical gloves should be removed when soiled or touching the environment, compliance is variable. The use of antimicrobial-impregnated medical gloves could reduce the horizontal-transfer of bacterial contamination between surfaces.

Aim

Determine the activity of antimicrobial-impregnated gloves against common hospital pathogens: Streptococcus pyogenes, carbapenem-resistant E.coli (CREC), MRSA and ESBL-producing Klebsiella pneumoniae.

Methods

Fingerpads (~1cm2) of PHMB-treated and untreated gloves were inoculated with 10 μL (~104 colony-forming-units [cfu]) of test-bacteria prepared in heavy-soiling (0.5%BSA), blood or distilled-water (no-soiling) and sampled after 0.25, 1, 10 or 15 min contact-time.

Donor surfaces (~1cm2 computer-keys) contaminated with wet/dry inoculum were touched with the fingerpad of treated/untreated gloves and subsequently pressed onto recipient (uncontaminated) computer-keys.

Results

Approximately 4.50log10cfu of all bacteria persisted after 15 min on untreated gloves regardless of soil-type. In the absence of soiling, PHMB-treated gloves reduced surface-contamination by ~4.5log10cfu (>99.99%) within 10 min of contact-time but only ~2.5log10 (>99.9%) and ~1.0log10 reduction respectively when heavy-soiling or blood was present.

Gloves became highly-contaminated (~4.52log10–4.91log10cfu) when handling recently-contaminated computer-keys. Untreated gloves contaminated “recipient” surfaces (~4.5log10cfu) while PHMB-treated gloves transferred fewer bacteria (2.4–3.6log10cfu). When surface contamination was dry, PHMB gloves transferred fewer bacteria (0.3–0.6log10cfu) to “recipient” surfaces than untreated gloves (1.0–1.9log10; P < 0.05).

Conclusions

Antimicrobial-impregnated gloves may be useful in preventing dissemination of organisms in the near-patient environment during routine care. However they are not a substitute for appropriate hand-hygiene procedures.

Peer Review reports

Introduction

In European hospitals, 5.7% of patients have a healthcare associated infection at any one time [1]. These infections form a quarter of all patient-adverse events and cost 7 billion Euros per year [2]. The emergence of multidrug resistant Gram negative pathogens has made efforts for the reduction of healthcare-associated infection a priority. Staff hand hygiene is thought to be the most effective method to prevent transmission of these pathogens. In critical care the most frequently touched surfaces are the bedside computer and equipment trolley [3]. Hand hygiene compliance between computer keyboards and surfaces within the vicinity and the patient is poor. Adoption of electronic patient records with hand held tablet computers on patient wards increases risk of transmission especially as bacteria and spores may survive there for several weeks. Although hospital infection prevention policies require removal of gloves and hand hygiene between patient contact and touching nearby surfaces, this may not be performed, particularly in the emergency situation. Soiling of gloves may not be visible to the wearer yet harbour pathogenic organisms. Soiled/contaminated gloves should be removed between activities but this may not be immediate. Once organisms are transferred to any nearby surface there is a potential for further dissemination [4, 5].

An antimicrobial additive to the glove material could reduce the risks associated with accidental contact with surfaces. The antimicrobial-efficacy of poly-[hexa-methylene]-biguanide-hydrochloride (PHMB)-treated non sterile medical gloves was tested against a range of bacteria associated with healthcare infections. The effect on transfer of organisms to and from computer-keyboard surfaces under various levels of soiling is assessed.

Methods

Preparation and validity-testing of the glove material

Preparation of test organisms

Clinical isolates of carbapenem-resistant E.coli (CREC), meticillin-resistant Staphylococcus aureus (MRSA; EMRSA-15 variant B1), an extended-spectrum beta-lactamase (ESBL)-producing Klebsiella pneumoniae and a type-culture of Streptococcus pyogenes ATCC 19615 were tested.

Overnight culture of the test bacteria (10 μL) was transferred to sterile nutrient broth (10 mL; Oxoid, UK), mixed thoroughly and incubated aerobically at 37 °C for 18 h. Broth cultures were centrifuged at 3000 rpm (1500 × g; Jouan CR3i centrifuge: Thermo, UK) for 10 min and the remaining pellet re-suspended in 10 mL of 0.5% w/v Bovine Serum Albumin (BSA) (Sigma-Aldrich, UK), sterile horse blood (Oxoid, UK), or no soil (sterile distilled water).

Preparation of neutralising solution

Where appropriate, antimicrobial activity was inactivated with a neutralising solution comprising: 3% (w/v) Tween 80, 0.3% (w/v) Lecithin, 1.0% (w/v) Sodium thiosulfate, 1.5% (w/v) K2HPO4, KH2PO4 0.05% (w/v), 1% (w/v) Poly-[sodium-4-styrenesulfonate], 0.1% (v/v) Triton® ×100 (Sigma-Aldrich, UK) and prepared in Phosphate-buffered saline (PBS) solution (Oxoid, UK). Solutions were sterilised by autoclaving (121 °C for 15 min) and refrigerated (2–5 °C) until required.

Validation of neutraliser efficacy and toxicity

The capacity of the neutraliser to quench the antimicrobial activity of PHMB was confirmed and any toxicity against the test organisms assessed as previously described [6]. An excised square (1 cm x1cm) from an un-used PHMB-treated nitrile glove was immersed in 1 mL sterile de-ionised water and incubated at room temperature for 1 h to allow PHMB to leach into the solution (PHMB leachate). A sterile test tube was dosed with: (A) 1 mL Neutraliser +1 mL PHMB leachate + excised test-glove, (B) 1 mL Neutraliser A + 1 mL Sterile distilled water or (C) 2 mL distilled water (control) and incubated at room temperature for 1 min to allow neutralisation of the PHMB-leachate solution. This was inoculated with 1 mL (103 colony-forming units [cfu]) of S. pyogenes, CREC, MRSA or K. pneumoniae suspension prepared in sterile distilled water.

The resulting suspensions were incubated a further 10 min at room temperature before spread-plating 0.1 mL onto either Staph/Strep agar (S. pyogenes only) or Columbia blood agar plates (CREC, MRSA or K. pneumoniae). Plates were incubated aerobically at 37 °C for 48 h.

Neutraliser efficacy (NE) and neutraliser toxicity (NT) were calculated as:

$$ NE={M}_A/{M}_B, and $$
$$ NT={M}_B/{M}_{C,} where $$

MA, MB and MC represent the mean number of spores recovered from preparations (A), (B) and control populations (C) respectively. Results were based on 10 replicate test samples.

Using documented criteria6, the neutraliser efficacy and toxicity ratios were calculated as being ≥0.75 for all test-preparations (results not shown) demonstrating that the neutraliser was effective against PHMB solution and non-toxic to the test organisms.

Testing of the glove material

Effect of contact time on bacterial inoculum

The finger pad of the index finger of PHMB-treated and untreated (control) gloves was marked with a 1 cm × 1 cm test-area and the area rinsed 3 times with sterile distilled water followed by immersion in 70% ethanol solution before allowing to air-dry. Marked-areas were inoculated with 10uL (~104cfu) of the test organism (S. pyogenes, CREC, MRSA or K. pneumoniae) suspended in a soil solution (0.5% BSA or sterile horse blood) or in sterile distilled water (DW; control) and incubated at room temperature.

After the appropriate contact time (0.25, 1, 10 or 15 min) at room temperature, test-areas on the finger pad of gloves were excised, transferred to 2 mL neutralising solution and homogenised at high speed for 30 s by vortexing. Assays were incubated in neutraliser for 10 min at room temperature. Serial dilutions of suspensions were performed prior to spread-plating 0.1 mL aliquots either Staph/Strep selective agar (S. pyogenes only; Oxoid, UK) or Columbia blood agar plates (CREC, MRSA or K. pneumoniae). Plates were incubated aerobically at 37 °C for 48 h prior to reading.

Transfer from gloves to recipient-surface

A standard computer keyboard key was prepared as an example recipient-surface. Keys were scrubbed manually using non-chlorinated detergent then rinsed three times using sterile distilled water followed by immersing in 70% ethanol solution and air-dried prior to use.

As previously described (section 2.1), test-areas on treated and untreated (control) gloves were inoculated with 10 μL (~104 cfu) of the test organism prepared in a soil or distilled water (no soil). The inoculated gloves were donned by the investigator either immediately (wet inoculum) or after allowing the inoculum to dry (15 min incubation at room temperature) and the seeded finger-pad pressed onto an un-inoculated recipient surface (computer key) for one second.

The recipient-surface was swabbed immediately with a sterile cotton-tipped swab (pre-moistened in neutralising solution) and the swab transferred to a universal tube containing 2 mL neutralising solution. Swab suspensions were homogenised by vortexing at high speed for 30 s and incubated a further 10 min at room temperature. Aliquots (0.5 mL) of the neat suspension and 0.1 mL from 1/10 and 1/100 serial dilutions were surface-plated onto the appropriate agar and incubated aerobically at 37 °C for 48 h prior to reading.

Transfer from donor-surfaces (computer-key) to gloves and computer key

A test-area was marked on a standard computer keyboard key (donor-surface) and a second key (recipient-surface) with a 1 cm × 1 cm square and decontaminated as described previously. Donor-surfaces were seeded with 10 μL (~104 cfu) test organism ±soil-challenge/control soil. An unused treated or untreated glove (control) was donned by the investigator and the finger-pad of the index-finger pressed onto a wet or dry inoculum on the seeded donor-surface for one second. Immediately, the same contaminated finger-pad was pressed onto a second uncontaminated key (recipient-surface).

Donor and recipient-surfaces were swabbed immediately with a sterile cotton-tipped swab (pre-moistened in neutralising solution) and the swab transferred to a universal tube containing 2 mL neutralising solution. Similarly, the finger-pad of each contaminated glove was excised and transferred to a universal tube containing 2 ml neutralising solution. Solutions were vortexed at high speed for 30 s and the resulting suspension incubated in the neutralising solution for 10 min at room temperature. Aliquots (0.5 ml and 0.1 ml) of neat and serial dilutions were plated for incubation as above.

Results

Effect of contact time on bacterial inoculum

Test gloves were inoculated with 2.8 × 104- 6.1 × 104 (i.e. 4.45 log10–4.78 log10) cfu bacteria. Approximately 4.50 log10 cfu bacteria could be recovered from both PHMB-treated and untreated gloves when sampled immediately (Table 1).

Table 1 Persistence of [Median Log10 CFU (Inter-Quartile range)] contaminating bacteria on PHMB-treated or untreated (control) gloves under increasing contact time and soil challenge, n = 10

Untreated gloves remained contaminated with high numbers (4.50 log10 cfu) for up to 15 min with the test organisms regardless of the soil type (distilled water, 0.5% BSA, Blood). The only exception was S. pyogenes, where the absence of a soil (distilled water only) caused numbers to decline by 2.5 log10 cfu over the same period.

PHMB-treated gloves effectively reduced the numbers of S. pyogenes, CREC and MRSA by 4.50 log10 to below the detection limit (2 cfu) and K. pneumoniae by 2.50 log10 within 10 min of contact time when a soil-challenge was absent (distilled water only).

When the organic challenge was increased to moderate soiling (0.5% BSA) PHMB-treated gloves achieved 2.5 log10 reductions (<99.9%) in S. pyogenes, CREC, MRSA and K. pneumoniae contamination after 15 min exposure. When a heavy soil was present (blood), reductions were only <1 log10.

Transfer from glove-tip to surface

Finger-pads of PHMB-treated and untreated (control) gloves were inoculated with approximately 2.5 × 104- 4.8 × 104 (i.e. 4.41 log10–4.68 log10) cfu bacteria prior to touching the recipient surface. Regardless of the soil type, similar numbers of bacteria could be transferred from an untreated or PHMB-treated glove to an uncontaminated keyboard key when the inoculum was wet (Table 2).

Table 2 Transfer of bacteria from recently contaminated fingertips (wet inoculum) and old contamination (dry inoculum) to a donor surface (keyboard key) and when in the presence of different soiling conditions; n = 10

When the contaminating inoculum was dry, untreated-gloves were able to transfer the same numbers of bacteria to a keyboard surface as when the contamination was wet (under all soil conditions; Table 2). However, no contamination was detected (detection limit: 2 cfu) on keyboard keys that were touched with a dried inoculum on PHMB-treated gloves (distilled water and 0.5% BSA soil). When dry contaminated PHMB-treated gloves were soiled with blood, between 1.5–2.5 log10 bacteria could be transferred to the recipient surface.

Transfer from contaminated surfaces to gloves or other surface

Keyboard keys were contaminated with approximately 3.3 × 104- 8.2 × 104 (i.e. 4.52 log10–4.91 log10) cfu bacteria (S. pyogenes, CREC, MRSA and K. pneumoniae) suspended in 0.5% BSA, blood or no soil (distilled water).

When recently contaminated (i.e. wet) keyboard keys were touched with the fingertip of PHMB-treated and untreated gloves, approximately 3–4 log10 bacteria were transferred to these finger tips (Table 3). Where the inoculum on the keyboard surface was dry (15 min incubation at room temperature) fewer numbers of bacteria could be transferred to the fingerpad (2.5–3.3 log10 bacteria) of both test and control gloves.

Table 3 Transfer from a donor surface (keyboard key) contaminated recently with bacteria (wet inoculum) or from old contamination (dry inoculum) to the fingertip of a gloved hand and when in the presence of different soiling conditions; n = 10

Transfer of bacteria from donor to recipient surfaces via gloves

Touching a wet donor (i.e. previously contaminated) keyboard key with the fingertip of either PHMB-treated or untreated gloves and then immediately touching an uncontaminated recipient keyboard key transferred approximately 2.4–3.6 log10 cfu bacteria (Table 3).

In the presence or absence of a moderate soiling (i.e. 0.5% BSA or DW respectively) on the donor surface, between 1.0–1.9 log10 cfu bacteria (S. pyogenes, CREC and K. pneumoniae) could be transferred with an untreated glove to the recipient surface when the contamination was dry (i.e. present on surface for 15 min).

Under the same conditions, between 0.3–0.6 log10 cfu bacteria were transferred to recipient surfaces using the PHMB-treated gloves. The numbers of MRSA transferred from donor to recipient surfaces were the same whether treated or untreated gloves were donned. No difference was observed in the numbers of bacteria transferred from donor to recipient surfaces using either treated or untreated gloves when blood soiling was present (P > 0.05).

Discussion

The most frequent causes of healthcare-associated infections are E. coli (15.9%), S. aureus (12.3%) and Klebsiella spp. (8.7%) [1]. All of these may be spread on hands. Hand hygiene compliance varies widely depending on the staff category, clinical setting, and whether gloves are worn during patient care [7, 8].

Gloves are an essential part of personal protective equipment but not a substitute for hand hygiene. The use of medical examination gloves during patient-care is recommended as a “barrier” to infectious organisms in cases where contact with bodily fluids, mucous membranes or damaged skin is likely. However gloves should always be removed and hands decontaminated when moving away from the immediate patient-environment [9, 10]. The inappropriate use of gloves has been implicated in the cross transmission of clinically significant pathogens in the ICU setting [11]. In one study, it was shown only 5% of healthcare workers wearing gloves were likely to contaminate the skin of their hands after routine patient care compared to not wearing gloves (37%), demonstrating the benefits of a “barrier-protection” [12].

The various activities associated with patient care increase the likelihood of transmission of organisms from an infected patient to surfaces in their vicinity, especially in situations where there is repeated contact between staff, patient and environment. For example, during induction of anaesthesia the number of gloved-hand contact between the patient and environment is too frequent to allow hand-hygiene on every occasion.

In an effort to prevent the transmission of micro-organisms during procedures involving patient contact, double-gloving of the hands was implemented in an anaesthetic operating room. Removal of the outer glove of a double-layer significantly reduced the presence of contaminating organisms in the intraoperative environment, suggesting the rapid elimination of microorganisms on the surfaces of the hands may reduce the risk of cross-transmission from surfaces near patients. However, the implementation of double-layer gloving to complement hand hygiene may not be practical in emergency care situations. Consequently, the use of gloves impregnated with antimicrobial agents would be expected to reduce the risk of transmission from a patient to their environment and then to another patient [8].

PHMB is a broad spectrum antimicrobial agent supported under Directive 98/8/EC for use as a disinfectant. It is used as a preservative and as an antimicrobial agent in wet wipes, to prevent microbial contamination in wound irrigant or gel and sterile dressings, and to disinfect hard surfaces for food handling in institutions and hospitals. In a randomised controlled trial of impregnated dressings, it was superior to silver in reduction of bacterial load in chronic wounds [13]. However the EU Scientific Committee did not recommend its use in cosmetics as 0.3% preservative or spray-formulation [14].

In this study we showed PHMB-treated nitrile gloves can reduce S. pyogenes, CREC and MRSA contamination by ~4.5 log10 cfu (~99.99% reduction) to below the detection limit (2 cfu) within 10 min of contact time. There is an approximate 2.5 log10 cfu reduction of K. pneumoniae. This demonstrates a potential for PHMB-treated gloves to reduce the risk of contaminating nearby surfaces. Both PHMB-treated and untreated glove types could transfer high numbers of contaminating bacteria to uncontaminated surfaces if still wet. However, PHMB-treated gloves that were donned for 15 min (i.e. when the contaminating inoculum was visibly dry) did not transfer bacteria to uncontaminated surfaces in the absence of soil or when only moderate soiling (0.5% BSA) was present.

The concentration of contaminating organisms carried in an inoculum may influence the degree of cross-contamination. Hands or gloves contaminated with a small inoculum concentration may result in greater percentage transfer to an un-contaminated surface than a large inoculum [15]. Therefore, reductions in bacterial numbers to low numbers on a glove using antimicrobial PHMB may not directly correlate to a relative risk-reduction in potential cross-contamination of these organisms. Nonetheless, the efficacies demonstrated in our study show numbers may be reduced to below the detection limit (2 cfu) in short contact times (i.e. 10 min). The risk of spread could be further minimised if gloves are removed and changed between frequently and between activities.

A criticism of the study is that glove fingertip pads were homogenized to remove bacteria instead of using a swabbing technique. Homogenisation of the excised fingerpad of the glove allows the capture of bacterial cells from the microscopic contours of the glove material that may otherwise be inaccessible if using a swab. The antimicrobial PHMB additive was impregnated uniformly throughout the treated-glove material during manufacture and not applied superficially, thus minimising variation between structure and microscopic surface with the untreated (control) glove. More bacteria may be deposited from a glove than from a bare hand [16]. While swabbing will indicate the potential transfer of superficial contaminating cells homogenisation will permit the isolation of cells transferred in successive contacts to uncontaminated surfaces.

The application of antimicrobial PHMB in medical examination gloves has been evaluated recently [17]. However, in that assessment, the contaminating numbers were low (up to 102 cfu) and did not address the potential risks of cross-transfer to uncontaminated surfaces. In another study the antimicrobial efficacy of PHMB impregnated gloves was enhanced with the application of pressure (75 g weight for 1 min) to increase contact with the inoculum and therefore facilitating antimicrobial activity [18].

The antimicrobial potential of gloves impregnated with a variety of antimicrobial agents other than PHMB have been explored, though the design and test-criteria for the selection and development of antimicrobial gloves vary depending on the end-use and requirement pre-determined by the investigator.

Gentian violet and chlorhexidine impregnated into PVA gloves demonstrated rapid bactericidal activity against several clinically relevant pathogens (MRSA, vancomycin-resistant enterocci, multidrug-resistant Pseudomonas aeruginosa, and a carbapenemase producing Klebsiella pneumoniae) when assessed following the criteria described within the JIS Z 2801 standard for the determination of antimicrobial non-porous surfaces [19]. However, this test requires the application of glass cover-slips to increase surface contact and does not incorporate an interfering-substance/soil challenge, therefore permitting “enhanced” in-vitro antimicrobial activity that may not be achievable under realistic conditions. In the current study, antimicrobial activity was assessed without the application of enhanced pressure or cover slips to maximise contact. The presence of heavy soils, such as blood, limited bacterial reduction on PHMB-treated gloves to <1 log10 cfu. Nonetheless, the transfer of bacteria from PHMB-treated glove was significantly less compared with untreated gloves regardless of whether the contamination was recent or up to 15 min old (P < 0.05).

During use, micro-perforation of the medical examination glove is common [20, 21]. Loss of structural integrity may result in the bi-directional migration of contaminating organisms between the hands of the HCW, the patient and proximal surfaces in the clinical environment. In one study, chlorhexidine gluconate in a matrix on the inside of gloves was used to protect the staff member from accidental puncture contamination with body fluids [22]. In another study, coating antimicrobial chlorhexidine digluconate onto the inner surfaces of a glove demonstrated antimicrobial efficacy against S. aureus and K. pneumoniae for up to two-hours of continued use in a surgical setting [23].

A study by Reitzel, et al. showed rapid bactericidal activity for gloves impregnated with brilliant green and chlorhexidine but the organic solvents required in the process compromised glove integrity [19]. Compatibility of the glove material with the antimicrobial agent and the intended use should therefore be addressed prior, as disintegration of the glove material may expose the wearer to potentially pathogenic organisms. In the current study, the inner surfaces of the treated gloves used in the current study were not assessed for antimicrobial activity. However, the PHMB agent used was distributed throughout the inner and outer surfaces of the glove. This property indicates PHMB-impregnated gloves may reduce the risk of bacterial transfer upon puncture of the glove material. Although not assessed, the nitrile examination gloves evaluated in our study were designed to be compatible with the PHMB antimicrobial additive and did not compromise the physical integrity of the material during testing.

In conclusion, the use of antimicrobial nitrile gloves has a potential benefit in the clinical environment in reducing accidental environmental contamination. Soiling (e.g. blood) significantly reduces the efficacy of such materials so the gloves will have less effect on transfer of organisms between different sites on the patient. The test criteria for the evaluations of antimicrobial activity should be based upon realistic measures and relevance to the application and setting.

The use of medical examination gloves treated with antimicrobial agents (e.g. PHMB) should be utilised in conjunction with appropriate hand hygiene practices and gloves changed frequently between activities and after prolonged use.

References

  1. European Centre for Disease Prevention and Control. Point prevalence survey in acute care hospitals: HAI-Net PPS 2013. http://www.ecdc.europa.eu/en/healthtopics/Healthcare-associated_infections/point-prevalence-survey/Pages/Point-prevalence-survey.aspx. Accessed 2 Oct 2015.

  2. Marschang S, Bernardo G. Prevention and control of healthcare-associated infection in Europe: a review of patients’ perspectives and existing differences. J Hosp Infect. 2015;89:357–62.

    Article  CAS  PubMed  Google Scholar 

  3. Fitzgerald G, Moore G, Wilson APR. Hand hygiene after touching a patient’s surroundings: the opportunities most commonly missed. J Hosp Infect. 2013;84:27–31.

    Article  CAS  PubMed  Google Scholar 

  4. Pessoa-Silva CL, Dharan S, Hugonnet S, et al. Dynamics of bacterial hand contamination during routine neonatal care. Infect Control Hosp Epidemiol. 2004;25:192–7.

    Article  PubMed  Google Scholar 

  5. Girou E, Chai SH, Oppein F, et al. Misuse of gloves: the foundation for poor compliance with hand hygiene and potential for microbial transmission? J Hosp Infect. 2004;57:162–9.

    Article  CAS  PubMed  Google Scholar 

  6. Sutton SVW, Proud DW, Rachui S, Brannan DK. Validation of microbial recovery from disinfectants. J Pharm Sci Tech. 2002;56:255–66.

    CAS  Google Scholar 

  7. Allegtanzi B, Pittet D. Role of hand hygiene in healthcare-associated infection prevention. J Hosp Infect. 2009;73:305–15.

    Article  Google Scholar 

  8. Jeanes A, Coen PG, Wilson AP, Drey NS, Gould DJ. Collecting the data but missing the point: validity of hand hygiene audit data. J Hosp Infect. 2015;90:156–62.

    Article  CAS  PubMed  Google Scholar 

  9. Loveday HP, Lynam S, Singleton J, et al. Clinical glove use: healthcare workers’ actions and perceptions. J Hosp Infect. 2014;86:110–6.

    Article  CAS  PubMed  Google Scholar 

  10. Birnbach DJ, Rosen LF, Fitzpatrick M, Carling P, Arheart K, Munoz-Price LS. Double gloves: a randomized trial to evaluate a simple strategy to reduce contamination in the operating room. Anesth Analg. 2015;120:848–52.

    Article  PubMed  Google Scholar 

  11. Ye D, Shan J, Huang LJ, Li C, Liu X, He W, Li Y, Mao P. A gloves-associated outbreak of imipenem-resistant Acinetobacter Baumannii in an intensive care unit in Guangdong. China BMC Infec Dis. 2015;15:179.

    Article  Google Scholar 

  12. Hayden M, Blom D, Lyle E, Moore C, Weinstein R. Risk of hand or glove contamination after contact with patients colonized with Vancomycin-resistant Enterococcus or the colonized patients’ environment. Infec Control Hosp Epidemiol. 2008;29(2):149–54.

    Article  Google Scholar 

  13. Eberlein T, Haemmerle G, Signer M, et al. Comparison of PHMB-containing dressing and silver dressings in patients with critically colonised or locally infected wounds. J Wound Care. 2012;21:12,14-6–18-20.

    Article  Google Scholar 

  14. Scientific Committee on Consumer Safety. Opinion on the safety of 355 poly(hexamethylene) biguanide hydrochloride (PHMB). doi:10.2772/4883 2nd 356 Revision 13/7/15. http://ec.europa.eu/health/scientific_committees/consumer_safety/docs/sccs_o_157.pdf. Accessed 24 Oct 2015.

  15. Montville R, Schaffner DW. Inoculum size influences bacterial cross contamination between surfaces. Appl Environ Microbiol. 2003;69(12):7188–93. http://doi.org/10.1128/AEM.69.12.7188-7193.2003

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  16. Wilson APR, Ostro P, Magnussen M, Cooper B. Laboratory and in use assessment of methicillin-resistant Staphylococcus aureus contamination of ergonomic computer keyboards for ward use. Am J Infection Control. 2008;36:e19–25.

    Article  Google Scholar 

  17. Kahar B-M, et al. Evaluation of the efficacy of antibacterial medical gloves in the ICU setting. J Hosp Infect. 2015;90(3):248–52.

    Article  Google Scholar 

  18. Leitgeb-J SR, Eng A-H, Yee B-N, The Y-P, Dosch V, Assadian O. In-vitro experimental evaluation of skin-to-surface recovery of four bacterial species by antibacterial and non-antibacterial medical examination gloves. Antimicrob Resist Infect Control. 2013;2:27.

    Article  PubMed Central  PubMed  Google Scholar 

  19. Reitzel R, Rosenblatt J, Jiang Y, Hachem R, Raad I. Disposable gendine antimicrobial gloves for preventing transmission of pathogens in health care settings. Am J Infect Control. 2014;42:55–9.

    Article  CAS  PubMed  Google Scholar 

  20. Harnoss J, Partecke LI, Heidecke CD, Huebner NO, Kramer A, Assadian O. Concentration of bacteria passing through puncture holes in surgical gloves. Am J Infect Control. 2010;38:154–8.

    Article  PubMed  Google Scholar 

  21. Misteli H, Weber WP, Reck S, Rosenthal R, Zwahlen M, Fueglistaler P, et al. Surgical glove perforation and the risk of surgical site infection. Arch Surg. 2009;144:553–8.

    Article  PubMed  Google Scholar 

  22. Modak S, Sampath L, Miller HS, Millman I. Rapid inactivation of infectious pathogens by chlorhexidine-coated gloves. Infect Control Hosp Epidemiol. 1992;13:463–71.

    Article  CAS  PubMed  Google Scholar 

  23. Leitgeb J, Schuster R, Yee B-N, Chee PF, Harnoss J-C, Starzengruber P, Schaffer M, Assadian O. Antibacterial activity of a sterile antimicrobial polyisoprene surgical glove against transient flora following a 2-hours simulated use. BMC Surg. 2015;15:81.

    Article  PubMed Central  PubMed  Google Scholar 

Download references

Acknowledgements

A poster was presented at the Healthcare Infection Society Conference in Lyon between 16 and 18 November 2014 (number 3405).

Funding

This research was funded by unrestricted grants from Ansell (Ansell Science & Technology Innovation Centre, Malaysia) and supported by the National Institute for Health Research University College London Hospitals Biomedical Research Centre. PHMB-treated gloves were provided free-of-charge by Ansell and financial support provided to subsidise microbiological media costs. However, Ansell was not involved in the study design, research outcome or writing and editing of any part of the manuscript.

Availability of data and materials

The datasets used and analysed during the current study may be made available from the corresponding author upon request in writing and approval sought from all corresponding authors.

Author information

Authors and Affiliations

Authors

Contributions

S. Ali co-conceived the project with APR Wilson and equally involved in the interpretation of the data, writing and editing of the final manuscript. S. Ali performed the testing, reading and reporting of results. Both authors read and approved the final manuscript.

Corresponding author

Correspondence to S. Ali.

Ethics declarations

Ethics approval and consent to participate

None required: No human or animal participants involved in this study.

Consent for publication

Not applicable

Competing interests

Both authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ali, S., Wilson, A. Effect of poly-hexamethylene biguanide hydrochloride (PHMB) treated non-sterile medical gloves upon the transmission of Streptococcus pyogenes, carbapenem-resistant E. coli, MRSA and Klebsiella pneumoniae from contact surfaces. BMC Infect Dis 17, 574 (2017). https://doi.org/10.1186/s12879-017-2661-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12879-017-2661-9

Keywords