Skip to main content

Table 3 SERODIA-TP·PA® versus ADVIA Centaur® Syphilis CLIA assay results, including the testing of discordant cases with the complete testing algorithm

From: A multi-country comparative study of two treponemal tests for the serodiagnosis of syphilis amongst men who have sex with men (MSM): Chemo-luminescent assay vs Treponema pallidum particle agglutination assay

SERODIA-TP·PA® + complete testing algorithm

ADVIA Centaur® Syphilis CLIA

 

(Reference testa)

(Index test)

 

Positive

Negative

Total

Positive

362

1

363

Negative

4

1,118

1,122

Total

366

1,119

1,485

  1. aComplete testing algorithm phase 1 and phase 2, Fig. 1: (SERODIA-TP-PA + Western Blot + Immunoblot)