Skip to main content

Table 3 Diagnostic Accuracy of Combined Preoperative Tests according to type of PJI

From: The poor accuracy of D-dimer for the diagnosis of prosthetic joint infection but its potential usefulness in early postoperative infections following revision arthroplasty for aseptic loosening

Markers

Specificity (%) (95% CI)

Sensitivity (%) (95% CI)

PPV (%) (95% CI)

NPV (%) (95% CI)

AUC (95% CI)

D-dimer + CRP

 All PJI patients

92.7 (88.3–97)

59 (43.5–74.4)

69.7 (54–85.4)

88.8 (83.6–94)

0.885 (0.831–0.938)

 Early

92.7 (88.3–97)

57.1 (20.5–93.8)

28.6 (4.9–52.2)

97.7 (93–100)

0.944 (0.902–0.985)

 Delayed

92.7 (88.3–97)

44.4 (12–76.9)

28.6 (5–52.2)

96.2 (91.6–100)

0.914 (0.853–0.975)

 Late

92.7 (88.3–97)

65.2 (45.7–84.7)

60 (40.8–79.2)

94.1 (89.6–98.5)

0.855 (0.782–0.928)

D-dimer + ESR

 All PJI patients

88.3 (82.9–93.7)

61.5 (46.3–76.8)

60 (44.8–75.2)

89 (83.5–94.4)

0.812 (0.729–0.896)

 Early

88.3 (82.9–93.7)

71.4 (38–100)

23.8 (5.6–42)

98.4 (92–100)

0.917 (0.856–0.978)

 Delayed

88.3 (82.9–93.7)

44.4 (12–76.9)

20 (2.4–37.5)

96 (89.9–100)

0.872 (0.786–0.957)

 Late

88.3 (82.9–93.7)

65.2 (45.7–84.7)

48.4 (30.8–66)

93.8 (87.9–99.7)

0.7358 (0.633–0.882)

CRP + ESR

 All PJI patients

87.8 (82.4–93.3)

76.9 (63.7–90.1)

63.8 (50–77.6)

93.2 (87.3–99)

0.838 (0.757–0.919)

 Early

87.8 (82.4–93.3)

85.7 (59.8–100)

26 (8.1–44)

99,1 (92.77–100)

0.903 (0.83–0.976)

 Delayed

87.8 (82.4–93.3)

77.7 (50.6–100)

29.2 (11–47.3)

98.4 (92–100)

0.926 (0.869–0.984)

 Late

87.8 (82.4–93.3)

73.9 (56–91.8)

50 (33.2–66.8)

95.3 (89.2–100)

0.783 (0.66–0.919)

  1. PJI, Prosthetic joint infection; PPV, Positive predictive value; NPV, Negative predictive value; AUC, Area under the curve; CI, Confidence interval