Skip to main content

Table 2 Type and incidence of DA-HAIs

From: Surveillance of device associated infections and mortality in a major intensive care unit in the Republic of Cyprus

  Device-days Device use No. of infections % of infections Incidence per 100 patients Incidence per 1000 device-days Exact 95 CI
VAP 1584 0.70 16 37.2 8.08 10.10 5.8 16.4
CLABSI 1318 0.58 21 48.8 10.61 15.93 9.9 24.3
CAUTI 2259 0.99 6 14.0 3.03 2.66 1 5.8
  1. CAUTI catheter-associated urinary tract infection, CLABSI central catheter-associated bloodstream infection, VAP ventilator-associated pneumonia