Skip to main content

Table 5 Proportions of reduction factors exceeding pre-specified thresholds for each CL care solution and for each tested microorganism / without organic load

From: In-vitroanalysis of the microbicidal activity of 6 contact lens care solutions

 

S. aureus

P. aeruginosa

S. marcescens

C. albicans

F. solani

 

RF ≥ 3

RF ≥ 5

RF ≥ 3

RF ≥ 5

RF ≥ 3

RF ≥ 5

RF ≥ 1

RF ≥ 4

RF ≥ 1

RF ≥ 4

 

%

N

%

N

%

N

%

N

%

N

%

N

%

N

%

N

%

N

%

N

AOSEPT PLUS

100

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

BlueVision

0

6

0

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

Easy Sept

0

6

0

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

Oxysept Comfort

0

6

0

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

100

6

Optifree Replenish

0

6

0

6

91.7

12

75

12

91.7

12

8.3

12

100

12

25

12

100

12

91.7

12

Solocare Aqua

0

6

0

6

0

6

0

6

0

6

0

6

91.7

12

33.3

12

100

12

58.3

12

χ 2 test

< 0.001

< 0.001

< 0.001

< 0.001

< 0.001

< 0.001

0.690

< 0.001

1

0.024

  1. The intervals ≥ 3.0 log [CFU/ml] for bacteria and ≥ 1.0 log [CFU/ml] for fungi were assessed according to the criteria of the EN ISO 14729 Stand Alone Test [47]. The intervals ≥ 5.0 log [CFU/ml] for bacteria according to the criteria of the norms EN 1040 [58], EN 13727 [59] and EN 1276 [60] and ≥ 4.0 log [CFU/ml] for fungi according to the criteria of the norms EN 1275 [61], EN 13624 [62] and EN 1650 [63] were assessed.