Skip to main content

Table 2 Assessment of different variables at RTQII enrolled HIV testing sites in Ethiopia, August to December 2019 (nā€‰=ā€‰159)

From: HIV rapid test performance among health facilities enrolled in HIV rapid test quality improvement initiative (RTQII) in Ethiopia

Variable

Availability

Total

No

Yes

Ā 

Test Algorithm posted

41 (25.8%)

118 (74.2%)

159

Tester followed SOP

79 (49.7%)

80 (50.3%)

159

Trained on the new algorithm

50 (31.4%)

109 (68.6%)

159

All test kits are available at the testing site*

96 (60.4%)

63 (39.6%)

159

Participation in EQA(PT) in the last two years

88 (55.3%)

71 (44.7%)

159

Receive supportive supervision from the facilityā€™s lab

86 (54.4%)

72 (45.6%)

158

Dedicated area(table or bench)for HIV rapid test

57 (35.8%)

102(64.2%)

159

Sink with water supply in the testing area

56(35.2%)

103(64.8%)

159

Disinfectant for decontamination

49(30.8%)

110(69.2%)

159

Proper disposal of biological waste

38(23.9%)

121(76.1%)

159

Sharps container at testing site

22(13.8%)

137(86.2%)

159

  1. *Key: HTSs most of the times keep only one or two of the three HIV test kits at work stations