Skip to main content

Table 4 Consistency of the pentaplex qRT-PCR and singleplex qPCR for detecting blood samples

From: Development and clinical validation of a one-step pentaplex real-time reverse transcription PCR assay for detection of hepatitis virus B, C, E, Treponema pallidum, and a human housekeeping gene

 

No. (%) positive numbers in blood donors

No. (%) positive numbers in clinical samples

Subject

HBV

HCV

HEV

T. pallidum

HBV

HCV

HEV

T. pallidum

Pentaplex qRT-PCR

13(1.08)

3(0.25)

1(0.08)

0(0)

56(4.67)

9(0.75)

0(0)

0(0)

Singleplex qPCR

13(1.08)

3(0.25)

1(0.08)

0(0)

56(4.67)

9(0.75)

0(0)

0(0)

Sensitivity (% )

100%

100%

100%

100%

100%

100%

100%

100%

Specificity (% )

100%

100%

100%

100%

100%

100%

100%

100%

Agreement (% )

100%

100%

100%

100%

100%

100%

100%

100%