Skip to main content

Table 1 Modeling input and ventilation reference parameters

From: The vaccination threshold for SARS-CoV-2 depends on the indoor setting and room ventilation

 

Classroom

Prison

Restaurant

Average

Room volume (m3)

170

576

640

462

Room area (m2)

57

160

213

143

Occupancy (persons)

20

50

100

57

Occupancy (m2 person−1)

2.8

3.2

2.1

2.7

Exposure time (h)

5.5

36

1.5

14

Infectious occupant activity

Standing, speaking

Resting, oral breathing

Resting, loudly speaking

–

Median ERq log10 (quanta h−1)

0.41

-0.28

1.2

0.44

Natural ventilation AER (h−1)

0.5

0.5

0.5

0.5

Mechanical ventilation AER (h−1)

2.6

1.4

3.2

2.4

High air quality AER (h−1)

6.4

4.7

8.4

6.5

Natural ventilation (L s−1 p−1)

1.2

1.6

0.89

1.2

Mechanical ventilation (L s−1 p−1)

6.1

4.4

5.7

5.4

High air quality ventilation (L s−1 p−1)

15

15

15

15