Skip to main content

Table 1 Minimum Inhibitory Concentrations distributions determined for 110 Staphylococcus aureus isolates from bloodstream infections

From: Pharmacodynamic comparison of different antimicrobial regimens against Staphylococcus aureus bloodstream infections with elevated vancomycin minimum inhibitory concentration

AntimicrobialN° (%) of isolates
MIC value in mg/L
0.06250.1250.250.5124
Ceftaroline2 (2)51 (46)33 (30)11 (10)12 (11)1 (1)0
Daptomycin003 (3)26 (23)65 (59)12 (11)4 (4)
Linezolid-100a001 (1)015 (14)83 (75)11 (10)
Linezolid-80a001 (1)1 (1)42 (38)66 (60)0
Teicoplanin0071 (64)33 (30)5 (5)01 (1)
Vancomycin0004 (4)75 (68)25 (23)6 (5)
  1. MIC Minimum Inhibitory Concentrations, a: MIC Endpoint values for linezolid were read at the first well where the trailing begins without regard for pinpoint trailing, as CLSI M100-S26 instructions, being designated as linezolid-80; and at 100% inhibition of growth, identified as linezolid-100