Variables | Coefficient | p value(N = 24) |
---|---|---|
Height of walls | 11.57 | 0.01 |
Width of room | −4.57 | 0.02 |
Floor area | −0.38 | 0.01 |
Volume of room | −0.12 | 0.02 |
Surface area of walls | −0.13 | 0.62 |
Door area | 8.03 | 0.21 |
Window number | 2.79 | 0.09 |
Window area | 5.66 | 0.05 |
Combine area of wind/door | 5.44 | 0.02 |
Wind speed at door | 4.08 | 0.45 |
Wind speed 10m | 0.82 | 0.83 |
House Shape | 9.69 | 0.005 |
Materials of roof | 10.43 | 0.005 |
Metal vs. Thatch | ||
Other ventilation space | −1.80 | 0.75 |
Absent vs. Present | ||
Window area/wall surface | 372.65 | 0.0024 |
Window area/floor area | 145.68 | 0.0001 |
Window/volume | 414.23 | <0.0001 |
Temperature | ||
Inside | 0.03 | 0.96 |
Outside | −0.43 | 0.31 |
Difference | −1.00 | 0.10 |
Relative humidity | 0.12 | 0.49 |
Smoke direction | ||
In | 5.46 | 0.40 |
Out | 8.15 | 0.26 |