From: Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence

Figure 4

Experimental validation of CFD findings. Sequential particle measurement at 1 min interval during and after spiking with inert particles (dashed area). 4a: spiking the operating table, showing accumulation of particle in the upper part of the room (30 cm from the ceiling, black circles) compared to the lower part (30 cm from the floor, open circles). 4b: spiking the entry anteroom, showing transfer of particles from the upper part of the entry anteroom (black squares) towards the lower part of the room (open circles) when the door is opened (arrows).